RF1238 318.0 MHz SAW Filter
* * * * *
Ideal Front-End Filter for 318.0 MHz Wireless Receivers Low-Loss, Coupled-Resonator Quartz Design Simple External Impedance Matching Rugged TO39 Hermetic Package Complies with Directive 2002/95/EC (RoHS) Pb
The RF1238 is a low-loss, compact, and economical surface-acoustic-wave (SAW) filter designed to provide front-end selectivity in 318.0 MHz receivers. Receiver designs using this filter include superhet with 10.7 MHz or 500 kHz IF, direct conversion and superregen. Typical applications of these receivers are wireless remote-control and security devices operating in the USA under FCC Part 15, in Canada under DoC RSS-210, and in Australia. This coupled-resonator filter (CRF) uses selective null placement to provide suppression, typically greater than 40 dB, of the LO and image spurious responses of superhet receivers with 10.7 MHz IF. RFM's advanced SAW design and fabrication technology is utilized to achieve high performance and very low loss with simple external impedance matching (not included). Quartz construction provides excellent frequency stability over a wide temperature range.
TO39-3 Case
Electrical Characteristics
Characteristic Nominal Frequency at 25C Insertion Loss 3 dB Bandwidth Rejection at fC - 21.4 MHz (Image) at fC - 10.7 MHz (LO) Ultimate Temp. Characteristics Operating Case Temp. Turnover Temperature Turnover Frequency Freq. Temp. Coefficient Frequency Aging External Impedance Match Series Inductance Shunt Capacitance (Tab Side, Non Tab Side) Lid Symbolization (in addition to Lot and/or Date Codes) TC TO fO FTC IfAI L C 5 1 3, 4 -40 30 45 fC+4 0.032 10 86 6.8 on Pin 1 Side, 4.7 on Pin 2 Side RFM RF1238 1 Absolute Frequency Tolerance from 318.0 MHz Sym fC fC IL BW3 Notes 1, 2 1 1, 2 500 40 15 Minimum Typical 318.0 80 1.7 700 50 40 80 +85 60 C C kHz ppm/C2 ppm/yr nH pF dB 3.5 800 Maximum Units MHz kHz dB kHz
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes: 1. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture which is connected to a 50 test system with VSWR 1.2:1. The test fixture L and C are adjusted for minimum insertion loss at the filter center frequency, fc. Note that insertion loss, bandwidth, and passband shape are dependent on the impedance matching component values and quality. 2. The frequency fc is defined as the midpoint between the 3dB frequencies. 3. Where noted, specifications apply over the entire specified operating temperature range. 4. The turnover temperature, TO, is the temperature of maximum (or turnover) frequency, fo. The nominal frequency at any case temperature, Tc, may 5. 6. 7. 8. be calculated from: f = fo [1 - FTC (To - Tc)2]. Frequency aging is the change in fc with time and is specified at +65C or less. Aging may exceed the specification for prolonged temperatures above +65C. Typically, aging is greatest the first year after manufacture, decreasing significantly in subsequent years. The design, manufacturing process, and specifications of this device are subject to change without notice. One or more of the following U.S. Patents apply: 4,54,488, 4,616,197, and others pending. All equipment designs utilizing this product must be approved by the appropriate government agency prior to manufacture or sale.
RF Monolithics, Inc. Phone: (972) 233-2903 Fax: (972) 387-8148 RFM Europe Phone: 44 1963 251383 Fax: 44 1963 251510 (c)1999 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: info@rfm.com http://www.rfm.com RF1238-102401
Page 1 of 2
318.0 MHz
Absolute Maximum Ratings Rating
Incident RF Power
SAW Filter
Value
+13 30 -40 to +85
Units
dBm VDC C
DC Voltage Between Any Two Pins (Observe ESD Precautions) Case Temperature5
Typical Filter Response
Typical filter responses are shown below. The actual response is dependent on external impedance matching and circuit layout. Illustrated frequencies and minimum rejection for LO and IMAGE are shown only for superhet receivers with 10.7 MHz IF. .
0 dB -10
Amplitude Response
0 dB -1
LO
-20 -30 -40 -50 -60 -70 -80
Image
-2
Amplitude Response
-3 -4 -5 -6 -7 -8
Minimum 3dB Passband at 25 oC
5 MHz/div Frequency
100 KHz/div Frequency
Electrical Connections
Bottom View
Case Design
C B G
Pin 1 2 3
Connection Input or Output Output or Input Case Ground
Pin 1 Pin 2
H F
Pin 3 3
A D (3 places)
E
Typical Test Circuit
J (2 places)
45
L
From 50 Network Analyzer
1 2 3
L
Millimeters Dimensions
C
To 50 Network Analyzer
Inches Min Max 0.370 0.125 0.098 0.138 0.018 Nominal 0.200 Nominal 0.100 Nominal 0.100 Nominal 0.040 0.055
Min A B C D E F G H J 1.40 2.50
Max 9.40 3.18 3.50
C
0.46 Nominal 5.08 Nominal 2.54 Nominal 2.54 Nominal 1.02
RF Monolithics, Inc. Phone: (972) 233-2903 Fax: (972) 387-8148 RFM Europe Phone: 44 1963 251383 Fax: 44 1963 251510 (c)1999 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: info@rfm.com http://www.rfm.com RF1238-102401
Page 2 of 2


▲Up To Search▲   

 
Price & Availability of RF1238

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X